info@supersystemsuk.co.uk
Tel: +44 (0)121 329 2627
Fax: +44 (0)121 345 0778
Super Systems UK Gas carburising, nitriding, carbonitriding, nitrocarburising, vacuum treatment systems. SSi logo

MGA 6010 – Multi-gas Infra-red Analyser

MGA6010 showing full colour touchscreen interface

NEW – MGA6010 now has fully automatic zero and span calibration built in as standard. Just install it and leave it until the span gas bottle runs out.

Probe + IR System

  • Automatically adjust CO Factor (COF)
  • COF Limits predetermined for % Carbon adjustment
  • Millivolt and temperature limits for furnace gas sampling
  • Switch from Probe + IR control to “monitor” mode
  • OPTIONAL auto calibration box (P/N 13466)

MGA6000 Benefits: Heat Treat Furnaces – Conventional Endo Gas

  • Enhances quality through process repeatability and accuracy.
  • Furnace atmosphere diagnostics assists in maintenance troubleshooting.
  • Furnace process verification.
  • 3-gas measurement replaces manual adjustment of COF.
  • Sooting, air leaks, water leaks, and radiant tube leaks quickly identified through 3 gas measurement.
  • Elevated levels of CH4 provide indication of furnace or generator problems.

Heat Treat Furnaces – Nitrogen / Methanol Endo Gas (N2/CH3 OH)

  • Compensation of furnace carbon dependent on CO and furnace temperature.
  • Furnace atmosphere diagnostics assists in maintenance troubleshooting.
  • Furnace process verification.
  • 3-gas measurement replaces manual adjustment of COF.
  • N2 bubbles, sparger restrictions, unbalanced N2/MEOH system identified through 3-gas measurement.
  • 3-gas will show possible problems (i.e. sooting, water leaks, air leaks, and radiant tube leaks).

MGA 6000 - Multi-gas Infra-red Analyser - diagram